Draw the street face and the property face. A front view alone can’t show which side needs a door, access panel or gate connection.
Specify the role of each pier
On the site plan, label the mailbox pier, gate pier and any intermediate fence piers. Mark the street and driveway directions. Note which faces are visible, which receive fence returns and which must remain accessible after the gate or planting is in place.
Take dimensions from the actual insert
If an insert or intercom has been selected, send its manufacturer’s drawing, not only a product photo. Show the required opening and identify where the door swings or the device is serviced. If the hardware is undecided, mark the opening as pending instead of inferring it from an arch on the catalogue drawing.

Show the fence junction on a second view
Add one side elevation with the adjoining gate or fence line. Mark the finished grade and desired cap relationship across the entrance. Hinge loads, internal reinforcement, electrical routing and mountings are separate design questions, not details established by an exterior model.
- Give each pier an ID, orientation, reference and quantity.
- Identify insertion, collection and service faces for each device.