Record wall caps by run and cross-section. Record pier caps by the dimensions of the finished pier top and the number of matching tops.
For a wall, measure across as well as along
A total length helps with quantity, but it won’t tell the team which section fits. Measure across the finished wall, including facing material, and say whether the dimension is finished or still proposed. On a plan, mark straight runs, exposed ends, corners and steps in height. Label where a run stops against a pier instead of counting straight through it.
For a pier, draw the top as a rectangle
Give both finished top dimensions, even if the pier looks square. Mark which side faces the street and where the adjoining wall lands. If the cap is intended to carry a separate finial, call it out as another component; don’t assume it comes with the cap or that any two references fit together.

Compare the bearing face, not only the silhouette
The widest part of a moulded cap may sit above a narrower underside. Read the section against your finished wall or pier, then mark the overhang you want the team to review. A photograph of a finished gate helps explain the look, but cannot settle the bearing width or corner detail.
Make the junction explicit
A useful gate sketch might read “two matching pier tops, one left wall run, one right wall run.” Add a small elevation at the junction so the team can see whether the wall cap stops below the pier cap or aligns with it.
- Wall list: run ID, length, finished width, corners and ends.
- Pier list: top width × depth, quantity, cap reference and any separate finial.
- Include one drawing of the junction and identify any field dimensions still needed.