← All articles & guides

Use two layers on the elevation: one for the architectural grid, one for the actual panel pieces. It should be clear which dimensions refer to which layer.

Pick the controlling line

Mark the feature that should drive the elevation: a sill, door head, corner or long horizontal band. Continue the joint grid towards the next opening. A line that looks balanced on one bay can leave a narrow piece on the adjacent bay, so include at least one neighbouring opening in the sketch.

Give cut pieces their own IDs

Differentiate repeated full panels from sill strips, jambs, heads and end pieces. Mark their orientation. If a finish has a visible direction, show it on the elevation separately from the panel dimension; rotating the same size may change the appearance.

Landmark catalogue reference: 12 × 72 × 0.5 in
The catalogue lists nominal 12 × 72, 24 × 72, 36 × 72 and 72 × 8 inch formats at ½-inch thickness. These are selection envelopes, not allowable unsupported spans. Open original catalogue · page 7 ↗

Coordinate the joint before pricing a repeat

Mark where edges meet another material, turn a corner or pass an opening. Indicate whether a dimension is panel size, clear opening or an overall grid dimension that includes a joint. Support, attachment, final joint width and movements must be resolved for the project.

  • Send an elevation with opening sizes, joint lines and panel IDs.
  • Identify nominal format, orientation and proposed finish.
  • Flag cuts, returns and junctions that require a separate section.