Show the slab, support zone and underlying assembly separately. A catalogue drawing of a pedestal is not a complete engineered deck.
Draw the limiting edge first
Often the decision starts at a door, drain or parapet rather than the middle of the terrace. Mark the finished paving level and the level of the underlying assembly at that point. Show slopes and changes of elevation that affect the available build-up; don’t turn one height at a threshold into a blanket support height.
Lay out the grid around access points
On plan, show full pavers, perimeter cuts, penetrations and any area that needs to remain accessible. Identify awkward slivers at doors and edges. Moving a joint line on paper is easier than discovering that a small cut piece is expected to bridge an unreviewed condition.

Request the slab and support review separately
The catalogue includes a PB-3 support drawing alongside slab references. That establishes a source to discuss, not an approved support spacing, waterproofing detail or loading capacity. Give the design team the use of the terrace and the proposed assembly to review together.
- Supply the paving plan and a dimensioned section at each critical threshold.
- Identify drains, edge restraints, access points and special cuts.
- State the slab reference and list unresolved support or waterproofing questions separately.