Send one photo of the entire run and one square-on view of the profile end. A straightedge or scale in the same plane makes the second view far more useful.

Find the most informative end

Look for an exposed end, return or junction where the layers can be seen. Without removing installed material, photograph it straight on. Add a sketch of the finished wall plane, overall height and furthest projection. If the old profile is damaged, mark which edge is missing instead of reconstructing it from memory.

Explain what must match

Sometimes the important line is the drip or shadow at the bottom; sometimes it is the top edge meeting a sill on the next opening. Mark the controlling line on the photo. Record whether the aim is a close match to existing trim or a new interpretation across the whole façade.

Landmark catalogue reference: Window surrounds
The Limelight catalogue shows applications such as window surrounds. It does not assign a dimensioned stock profile to every photographed detail. Open original catalogue · page 13 ↗

Separate profile approval from surface approval

Limelight’s core and aggregate surface are a different system from a solid precast piece. Review the shape in section and ask for a Limelight material sample for the surface. Conditions at joints, ends, substrates and installation remain project-specific.

  • Name the run, its endpoints and adjacent material.
  • Attach an elevation, end profile and dimensions with units.
  • Identify returns, damaged portions and the finish you want to compare.